Navigation Menu

Drives  
Motion  

U1000 iQpump

U1000 iQpump

U1000 iQpump - LH - YAIALL

TemplateWeb

Keypads & Cables

U1000 iQpump-Options

This array of keypads and cables can extend the flexibility and adaptability of Yaskawa AC drives. These options may be factory installed or field installed.

Keypad Options

USB Copy Unit (Y-Stick)

USB Copy UnitThis option allows allows the drive to connect to the USB port on a PC. It can read, copy and verify drive parameter settings from one drive to another like drive. This unit plugs into the RJ-45 port on the front of the digital operator.

Model Number & Mounting Location Installation Guide & Technical Manual
JVOP-181
RJ-45 Keypad Port

IG.V1000.01

TOBPC73060025


JVOP-181 Kit Contents:
Qty
Description
1
USB Copy Unit (Y-Stick)
1
1 ft USB Cable to connect PC to Y-Stick
1
3 ft Cable with RJ-45 connector on both ends to connect Y-Stick to drive
1
Technical Manual (TOBPC73060025)
 

Driver: SP1824_001
Note: This driver is required to be installed on the PC before the Y-stick can be used.


CopyUnitManager PC Software

CopyUnitManager is a PC software program that works along with the Y-Stick Copy Unit (JVOP-181) that allows the user to transfer and save parameter files from the Y-Stick to a PC and vice versa. The CopyUnitManager software can be used to save parameter files for a variety of drive sizes and parameter configurations. Simply configure the drive parameters, transfer them to the Y-Stick Copy Unit, then save them to your PC for backup or for quickly downloading multiple drives.

Download Software (5.9MB)

System Requirements

  • PC: PC/AT DOS/V Compatible machine
  • CPU: Pentium II Processor 2GHz, 3GHz or more recommended
  • Memory: 512MB, 1GB or more recommended
  • Hard Disk Capacity: More than 400MB
  • Operating System: WindowsXP SP2, Windows2000 SP4

Digital Operator, LCD

This operator is the standard digital operator on all UL Type 3R enclosure doors. This option is only needed if the original keypad is lost or damaged.

Model Number & mounting Location Manual
UOP000023
JVOP-183R
Mounts to RJ-45 keypad port

TOEPYAIP1W01


UOP000023 Kit Contents:
Qty
Description
1 LCD digital operator display, 5 lines x 16 characters, backlit
1 Installation Manual (TOEPYAIP1W01)
 

UL Rated Remote Outdoor Operator / Mounting Kit

This option provides all you will need to remotely mount an iQpump1000 Digital Operator to the door/wall of a separately priced, oversized UL Type 1, 3R, 4, 4X, or 12 enclosure (IPX6 environment). This kit includes: One JVOP-183R Digital Operator providing RC, HOA, and outdoor rated LCD display, a faceplate bezel with digital operator cutout in the enclosure door, a 3-foot cable, a 10-foot cable, and a 1:1 template for cutting the necessary cutouts in the enclosure. Mounting hardware included. Kepad can be removed after kit installation. Connects to RJ-45 port and mounts to enclosure wall.

Model Number Manual
UOP000017 (Yaskawa Logo Faceplate Membrane)

UOP000019 (Blank Faceplate Membrane).
TOEPYEAOPT02
 

LCD Keypad Installation Set A (Remote Operator Mounting Bracket Kit).

This is a bracket to which the LCD Digital Remote Operator (JVOP-183) attaches, and has (4) threaded holes and screws to attach to the cover of an enclosure. The kit contains (2) screws to mount the operator to the bracket and (4) screws to attach the bracket to the enclosure.

Model Number Manual
EZZ020642A (Blank Membrane) Mounts to keypad port and enclosure door. TOEPYEAOPT02
 

LCD Keypad Installation Set B (Remote Operator Mounting Bracket Kit).

Contains a similar bracket that the keypad attaches to and has non-threaded holes for mounting to an enclosure that has the screws attached to the enclosure already. The kit contains (2) screws to mount the keypad to the bracket and (4) nuts to attach the bracket to the customer supplied screws attached to the enclosure.

Model Number Manual
EZZ020642B TOEPYEAOPT02
 

Operator Kits, UL Type 3R/4X.

This option is used to extend an LCD or LED Digital Remote Operator to the wall of a separately priced, oversized UL Type 3R, 4, 4X or 12 enclosure (IPX6 environment). Price includes a faceplate bezel with digital operator brackets and membrane to cover the operator cutout in the enclosure door, a 3-foot cable, a 10-foot cable, and a 1.1 template for cutting the necessary cutouts in the enclosure. Keypad can be removed after kit installation. Designed for use with the LCD Operator JVOP-183 or the LCD Operator JVOP-183R, sold separately. Connects to RJ-45 port and mounts to enclosure wall.

Model Number Manual
UUX000526 (Blank Membrane)

UUX000527 (Yaskawa Logo Membrane)
Keypad Template (UDM00236)
 

Overlay, Keypad, Self-Adhesive.

This membrane is used to cover the operator cutout in the enclosure door to which the keypad has been remotely mounted.

Model Number Manual
UNP00233-3

UNP00233-5
 
 

Key Pad Adapter Kit.

This kit can be used when a "new" iQpump1000 key pad is replacing an "old style" key pad used with P7-based iQpump drives. This kit will allow enclosure door mounted key pad to be upgraded from P7 style to the iQpump1000 style digital key pad.

Model Number Manual
UUX000922  
 

Cable Options

Cables Model Number
Remote Operator Cable
These cables are used to connect the Remote LCD Digital Operator (JVOP-180) or Remote LED Operator (JVOP-182). They are available in one (1) or three (3) meter lengths.
UWR0051
(1 meter),
UWR0052
(3 meter)
PC Interface Cable
This 6-foot cable interconnects the drive keypad port to the 9-pin communication port on a PC. This cable is used in conjunction with DriveWizard Industrial software.
UWR00468-2
USB Interface Cable
This 10-foot male USB-A to male USB-B cable provides a USB-to-USB connection from PC to the drive.
UWR-0638
Flash Write Cable
This 6-foot cable connects a PC's 9-pin serial port to the drive's keypad port for updating the drive's firmware, flashing with custom firmware, or updating a network communication option board. It is used with the Flash Tool feature of the DriveWizard Industrial software.
UWR01076-1