Z1000U Matrix Drive
Breadcrumb
Navigation Menu
Products
Z1000U Matrix Drive
Z1000U Matrix Drive
Z1000U Matrix Drive - LH - YAIMOB
7.5 to 350 HP
The Z1000U Matrix Drive incorporates matrix technology to directly convert input AC voltage to output AC voltage. The drive is ideally suited for HVAC applications providing extremely low harmonic distortion, energy savings, and serviceability in a space-saving design.
Our Z1000U Matrix Drive was Product of the Year by Consulting-Specifying Engineer.
For more product packages, see Z1000U Matrix Configured or Z1000U Matrix Bypass.
TemplateWeb
Models & Ratings
Z1000U Matrix - Overview
208V Standard Drives (IP00/Open Chassis)
Drive Model Number 4
|
Rated Output Current (Amps) 1, 2
|
Nominal HP 3
|
---|---|---|
CIMR-ZU2E0028AUA
|
28
|
7.5
|
CIMR-ZU2E0042AUA
|
42
|
10
|
CIMR-ZU2E0054AUA
|
54
|
15
|
CIMR-ZU2E0068AUA
|
68
|
20
|
CIMR-ZU2E0081AUA
|
81
|
25
|
CIMR-ZU2E0104AUA
|
104
|
30
|
CIMR-ZU2E0130AUA
|
130
|
40
|
CIMR-ZU2E0154AUA
|
154
|
50
|
CIMR-ZU2E0192AUA
|
192
|
60
|
CIMR-ZU2E0248AUA
|
248
|
75
|
1 The rated output current of the drive should be equal to or greater than the motor rated current.
2 Carrier frequency is set to 4 kHz. Current derating is required to raise the carrier frequency.
3 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
4 An EMC filter is included and is internal to the MATRIX drive.
480V Standard Drives (IP00/Open Chassis)
Drive Model Number 4
|
Rated Output Current (Amps) 1, 2
|
Nominal HP 3
|
---|---|---|
CIMR-ZU4E0011AUA
|
11
|
7.5
|
CIMR-ZU4E0014AUA
|
14
|
10
|
CIMR-ZU4E0021AUA
|
21
|
15
|
CIMR-ZU4E0027AUA
|
27
|
20
|
CIMR-ZU4E0034AUA
|
34
|
25
|
CIMR-ZU4E0040AUA
|
40
|
30
|
CIMR-ZU4E0052AUA
|
52
|
40
|
CIMR-ZU4E0065AUA
|
65
|
50
|
CIMR-ZU4E0077AUA
|
77
|
60
|
CIMR-ZU4E0096AUA
|
96
|
75
|
CIMR-ZU4E0124AUA
|
124
|
100
|
CIMR-ZU4E0156AUA
|
156
|
125
|
CIMR-ZU4E0180AUA
|
180
|
150
|
CIMR-ZU4E0216AUA
|
216
|
175
|
CIMR-ZU4E0240AUA
|
240
|
200
|
CIMR-ZU4E0302AUA
|
302
|
250
|
CIMR-ZU4E0361AUA
|
361
|
300
|
CIMR-ZU4E0414AUA
|
414
|
350
|
1 The rated output current of the drive should be equal to or greater than the motor rated current.
2 Carrier frequency is set to 4 kHz. Current derating is required to raise the carrier frequency.
3 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
4 An EMC filter is included and is internal to the MATRIX drive.
Node: dxpprd02:8080