Z1000U Matrix Configured
Breadcrumb
Navigation Menu
Products
Z1000U Matrix Configured
Z1000U Matrix Configured
Z1000U Matrix Configured - LH - YAIMOB
7.5 - 350 HP
The configured package provides a Z1000U Matrix drive containing HVAC application-specific software macros, a real-time clock, and Hand/Off/Auto LCD keypad with an input disconnect switch and space for several power options inside a UL Type 1, UL Type 12 or UL Type 3R enclosure. The drive incorporates matrix technology to directly convert input AC voltage to output AC voltage.
TemplateWeb
Dimensions & Weights
Z1000U Matrix Configured - Overview
208V: UL Type 1 | UL Type 3R 40°C Ambient
480V: UL Type 1 | UL Type 12 | UL Type 3R 40°C Ambient
208V, UL Type 1
Base Model Number
|
Nominal HP2
|
Physical Dimensions (in.)
|
Drawing Number
|
|||
---|---|---|---|---|---|---|
H
|
W
|
D
|
Weight (lbs.)1
|
|||
Z1E1D024PN
|
7.5
|
48
|
22
|
18
|
210
|
|
Z1E1D030PN
|
10
|
60
|
22
|
22
|
300
|
|
Z1E1D046PN
|
15
|
305
|
||||
Z1E1D059PN
|
20
|
315
|
||||
Z1E1D074PN
|
25
|
315
|
||||
Z1E1D088PN
|
30
|
60
|
30
|
20
|
420
|
|
Z1E1D114PN
|
40
|
430
|
||||
Z1E1D143PN
|
50
|
86
|
41
|
32
|
745
|
|
Z1E1D169PN
|
60
|
745
|
||||
Z1E1D211PN
|
75
|
945
|
1This data represents the drive weight only, not shipping weight.
2 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
208V, UL Type 3R (40°C Ambient1)
To determine correct corresponding dimension diagram below, use document # PD.Z1000.05 for 208V models.
Dimension Diagram2
|
Rough Dimensions (in.)
|
||
---|---|---|---|
H
|
W
|
D
|
|
38.0
|
28.5
|
20.8
|
|
44.9
|
31.3
|
23.2
|
|
54.2
|
35.0
|
24.4
|
|
68.2
|
38.0
|
24.4
|
|
92.0
|
41.3
|
36.5
|
|
92.0
|
41.3
|
47.4
|
|
93.5
|
66.3
|
48.2
|
1 For 50°C Ambient, please contact factory
2 To determine correct corresponding dimention diagram, use document # PD.Z1000.05 for 208V models.
480V, UL Type 1
Base Model Number
|
Nominal HP2
|
Physical Dimensions (in.)
|
Drawing Number
|
|||
---|---|---|---|---|---|---|
H
|
W
|
D
|
Weight (lbs.)1
|
|||
Z1E1B011PN
|
7.5
|
48
|
22
|
18
|
200
|
|
Z1E1B014PN
|
10
|
210
|
||||
Z1E1B021PN
|
15
|
210
|
||||
Z1E1B027PN
|
20
|
60
|
22
|
22
|
270
|
|
Z1E1B034PN
|
25
|
270
|
||||
Z1E1B040PN
|
30
|
285
|
||||
Z1E1B052PN
|
40
|
315
|
||||
Z1E1B065PN
|
50
|
325
|
||||
Z1E1B077PN
|
60
|
340
|
||||
Z1E1B096PN
|
75
|
60
|
30
|
20
|
425
|
|
Z1E1B124PN
|
100
|
440
|
||||
Z1E1B156PN
|
125
|
86
|
41
|
32
|
765
|
|
Z1E1B180PN
|
150
|
810
|
||||
Z1E1B240PN
|
200
|
990
|
||||
Z1E1B302PN
|
250
|
86
|
70
|
31
|
1440
|
|
Z1E1B361PN
|
300
|
1575
|
||||
Z1E1B414PN
|
350
|
1620
|
1This data represents the drive weight only, not shipping weight.
2 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
480V, UL Type 12
Base Model Number
|
Nominal HP2
|
Physical Dimensions (in.)
|
Drawing Number
|
|||
---|---|---|---|---|---|---|
H
|
W
|
D
|
Weight (lbs.)1
|
|||
Z1E2B011PN
|
7.5
|
40.2
|
23.3
|
19.1
|
214
|
|
Z1E2B014PN
|
10
|
|||||
Z1E2B021PN
|
15
|
215
|
||||
Z1E2B027PN
|
20
|
|||||
Z1E2B034PN
|
25
|
47.0
|
27.3
|
21.6
|
269
|
|
Z1E2B040PN
|
30
|
296
|
||||
Z1E2B052PN
|
40
|
300
|
||||
Z1E2B065PN
|
50
|
308
|
||||
Z1E2B077PN
|
60
|
311
|
||||
Z1E2B096PN
|
75
|
56.2
|
33.3
|
27.0
|
481
|
|
Z1E2B124PN
|
100
|
485
|
||||
Z1E2B156PN
|
125
|
84.0
|
37.9
|
26.9
|
888
|
|
Z1E2B180PN
|
150
|
897
|
1This data represents the drive weight only, not shipping weight.
2 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
480V, UL Type 3R (40°C Ambient1)
To determine correct corresponding dimension diagram below, use document # PD.Z1000.06 for 480V models.
Dimension Diagram2
|
Rough Dimensions (in.)
|
||
---|---|---|---|
H
|
W
|
D
|
|
38.0
|
28.5
|
20.8
|
|
44.9
|
31.3
|
23.2
|
|
54.2
|
35.0
|
24.4
|
|
68.2
|
38.0
|
24.4
|
|
92.0
|
41.3
|
36.5
|
|
92.0
|
41.3
|
47.4
|
|
93.5
|
66.3
|
48.2
|
1 For 50°C Ambient, please contact factory
2 To determine correct corresponding dimention diagram, use document # PD.Z1000.06 for 480V models.