U1000 Industrial MATRIX Drive
Breadcrumb
Navigation Menu
Products
U1000 Industrial MATRIX Drive
U1000 Industrial MATRIX Drive
U1000 Industrial MATRIX Drive - YAIALL
5 to 800 HP
The U1000 is a compact, total all-in-one solution for low harmonics and/or full regeneration, and is the ultimate choice for power quality and energy savings. Additionally, the U1000 delivers high flexibility and motor control performance to meet various application requirements.
Award Winning Technology | An Overview of Matrix Drive Technology
TemplateWeb
Models & Ratings
U1000 Industrial Matrix Drive - Overview
240V, 3-Phase
Drive Model Number Standard
|
Normal Duty (ND)
|
Heavy Duty (HD)
|
Standard Enclosure
|
||
---|---|---|---|---|---|
Rated Output Current (Amps)1, 2
|
Nominal HP3
|
Rated Output Current (Amps)1, 2
|
Nominal HP3
|
||
CIMR-UU2A0028AUA
|
28
|
10
|
22
|
7.5
|
IP00/Open Chassis
|
CIMR-UU2A0042AUA
|
42
|
15
|
28
|
10
|
|
CIMR-UU2A0054AUA
|
54
|
20
|
42
|
15
|
|
CIMR-UU2A0068AUA
|
68
|
25
|
54
|
20
|
IP00/Open Chassis
|
CIMR-UU2A0081AUA
|
81
|
30
|
68
|
25
|
|
CIMR-UU2A0104AUA
|
104
|
40
|
81
|
30
|
|
CIMR-UU2A0130AUA
|
130
|
50
|
104
|
40
|
IP00/Open Chassis
|
CIMR-UU2A0154AUA
|
154
|
60
|
130
|
50
|
|
CIMR-UU2A0192AUA
|
192
|
75
|
154
|
60
|
|
CIMR-UU2A0248AUA
|
248
|
100
|
192
|
75
|
IP00/Open Chassis
|
1 The rated output current of the drive should be equal to or greater than the motor rated current.
2 Carrier frequency is set to 3 kHz. Current derating is required to raise the carrier frequency.
3 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
480V, 3-Phase
Drive Model Number Standard
|
Normal Duty (ND)
|
Heavy Duty (HD)
|
Standard Enclosure
|
||
---|---|---|---|---|---|
Rated Output Current (Amps)1, 2
|
Nominal HP3
|
Rated Output Current (Amps)1, 2
|
Nominal HP3
|
||
CIMR-UU4A0011AUA
|
11
|
7.5
|
9.6
|
5
|
IP00/Open Chassis
|
CIMR-UU4A0014AUA
|
14
|
10
|
11
|
7.5
|
|
CIMR-UU4A0021AUA
|
21
|
15
|
14
|
10
|
|
CIMR-UU4A0027AUA
|
27
|
20
|
21
|
15
|
IP00/Open Chassis
|
CIMR-UU4A0034AUA
|
34
|
25
|
27
|
20
|
|
CIMR-UU4A0040AUA
|
40
|
30
|
34
|
25
|
|
CIMR-UU4A0052AUA
|
52
|
40
|
40
|
30
|
IP00/Open Chassis
|
CIMR-UU4A0065AUA
|
65
|
50
|
52
|
40
|
|
CIMR-UU4A0077AUA
|
77
|
60
|
65
|
50
|
|
CIMR-UU4A0096AUA
|
96
|
75
|
77
|
60
|
IP00/Open Chassis
|
CIMR-UU4A0124AUA
|
124
|
100
|
96
|
75
|
|
CIMR-UU4A0156AUA
|
156
|
125
|
124
|
100
|
|
CIMR-UU4A0180AUA
|
180
|
150
|
156
|
125
|
IP00/Open Chassis
|
CIMR-UU4A0216AUA
|
216
|
175
|
180
|
150
|
|
CIMR-UU4A0240AUA
|
240
|
200
|
216
|
175
|
|
CIMR-UU4A0302AUA
|
302
|
250
|
240
|
200
|
IP00/Open Chassis
|
CIMR-UU4A0361AUA
|
361
|
300
|
302
|
250
|
|
CIMR-UU4A0414AUA
|
414
|
350
|
361
|
300
|
|
CIMR-UU4A0477AUB
|
477
|
400
|
414
|
350
|
IP00/Open Chassis
|
CIMR-UU4A0590AUB
|
590
|
500
|
477
|
400
|
1 The rated output current of the drive should be equal to or greater than the motor rated current.
2 Current derating is required to raise the carrier frequency. Carrier frequency is set to 4 kHz. Carrier frequency is fixed at 3 kHz for 477A and 590A models.
3 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
System Kit Number
|
Drive Model Number Standard
|
Component Name
|
Normal Duty (ND)1
|
Heavy Duty (HD)1
|
Standard Enclosure
|
||
---|---|---|---|---|---|---|---|
Rated Output Current (Amps)3,4
|
Nominal HP2
|
Rated Output Current (Amps)3,4
|
Nominal HP2
|
||||
U1000-460V-720A |
CIMR-UU4A0720AUB
|
Matrix Drive Power Module |
720
|
600
|
590
|
500
|
IP00/Open Chassis
|
EUJ711800.M5 | PWM Filter Module | ||||||
U1000-460V-930A |
CIMR-UU4A0930AUB
|
Matrix Drive Power Module |
930
|
800
|
900
|
750
|
|
EUJ711820.M5 | PWM Filter Module |
1 Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds.
2 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors at 480 volts.
3 The rated output current of the drive should be equal or greater than the motor rated current.
4 Current derating is required to raise the carrier frequency. Carrier frequency is fixed at 3kHz for 720A and 930A models.
5 The EUJ☐☐☐☐☐☐.M PWM Filter Moduels for Models 4☐0720 to 4☐0930 are REQUIRED system components.
Node: dxpprd02:8080