Navigation Menu

Drives  
Motion  

U1000 Industrial MATRIX Drive

U1000 Industrial MATRIX Drive

U1000 Industrial MATRIX Drive - YAIALL

TemplateWeb

Models & Ratings

U1000 Industrial Matrix Drive - Overview

240V | 480V

240V, 3-Phase

Drive Model Number Standard
Normal Duty (ND)
Heavy Duty (HD)
Standard Enclosure
Rated Output Current (Amps)1, 2
Nominal HP3
Rated Output Current (Amps)1, 2
Nominal HP3
CIMR-UU2A0028AUA
28
10
22
7.5
IP00/Open Chassis
CIMR-UU2A0042AUA
42
15
28
10
CIMR-UU2A0054AUA
54
20
42
15
CIMR-UU2A0068AUA
68
25
54
20
IP00/Open Chassis
CIMR-UU2A0081AUA
81
30
68
25
CIMR-UU2A0104AUA
104
40
81
30
CIMR-UU2A0130AUA
130
50
104
40
IP00/Open Chassis
CIMR-UU2A0154AUA
154
60
130
50
CIMR-UU2A0192AUA
192
75
154
60
CIMR-UU2A0248AUA
248
100
192
75
IP00/Open Chassis
1 The rated output current of the drive should be equal to or greater than the motor rated current.
2 Carrier frequency is set to 3 kHz. Current derating is required to raise the carrier frequency.
3 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.

Back to Top

480V, 3-Phase

Drive Model Number Standard
Normal Duty (ND)
Heavy Duty (HD)
Standard Enclosure
Rated Output Current (Amps)1, 2
Nominal HP3
Rated Output Current (Amps)1, 2
Nominal HP3
CIMR-UU4A0011AUA
11
7.5
9.6
5
IP00/Open Chassis
CIMR-UU4A0014AUA
14
10
11
7.5
CIMR-UU4A0021AUA
21
15
14
10
CIMR-UU4A0027AUA
27
20
21
15
IP00/Open Chassis
CIMR-UU4A0034AUA
34
25
27
20
CIMR-UU4A0040AUA
40
30
34
25
CIMR-UU4A0052AUA
52
40
40
30
IP00/Open Chassis
CIMR-UU4A0065AUA
65
50
52
40
CIMR-UU4A0077AUA
77
60
65
50
CIMR-UU4A0096AUA
96
75
77
60
IP00/Open Chassis
CIMR-UU4A0124AUA
124
100
96
75
CIMR-UU4A0156AUA
156
125
124
100
CIMR-UU4A0180AUA
180
150
156
125
IP00/Open Chassis
CIMR-UU4A0216AUA
216
175
180
150
CIMR-UU4A0240AUA
240
200
216
175
CIMR-UU4A0302AUA
302
250
240
200
IP00/Open Chassis
CIMR-UU4A0361AUA
361
300
302
250
CIMR-UU4A0414AUA
414
350
361
300
CIMR-UU4A0477AUB
477
400
414
350
IP00/Open Chassis
CIMR-UU4A0590AUB
590
500
477
400
1 The rated output current of the drive should be equal to or greater than the motor rated current.
2 Current derating is required to raise the carrier frequency. Carrier frequency is set to 4 kHz. Carrier frequency is fixed at 3 kHz for 477A and 590A models.

3 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.

System Kit Number
Drive Model Number Standard
Component Name
Normal Duty (ND)1
Heavy Duty (HD)1
Standard Enclosure
Rated Output Current (Amps)3,4
Nominal HP2
Rated Output Current (Amps)3,4
Nominal HP2
U1000-460V-720A
CIMR-UU4A0720AUB
Matrix Drive Power Module
720
600
590
500
IP00/Open Chassis
EUJ711800.M5 PWM Filter Module
U1000-460V-930A
CIMR-UU4A0930AUB
Matrix Drive Power Module
930
800
900
750
EUJ711820.M5 PWM Filter Module
1 Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds.
2 Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors at 480 volts.
3 The rated output current of the drive should be equal or greater than the motor rated current.
4 Current derating is required to raise the carrier frequency. Carrier frequency is fixed at 3kHz for 720A and 930A models.
5 The EUJ☐☐☐☐☐☐.M PWM Filter Moduels for Models 4☐0720 to 4☐0930 are REQUIRED system components.

Back to Top